● Two models Multimeter (CP30) and Oscilloscope (CP35
and CP305)
● AC/DC low current measurement down to mAmps
● Excellent Accuracy with 1mA resolution (CP30/CP35)
● DC Auto Zero and Auto Power Off
● Compact lightweight design
● Broad bandwidth and low phase shift for power and
harmonics measurement
● Superior noise rejection for power electronics
applications

Advanced patented magnetic circuit design results in probes
accuracy to be little affected by external magnetic fields
or off-centre conductor positioning

● Light industrial and residential electrical installation
testing
● Leakage current measurements
● Process control for 4 - 20 mA current loop verification
● Battery charging systems
● Analysis of switching waveforms in inverters, switch mode
power supplies and industrial controls
● Automotive applications eg., Leakage current measurement
on car battery lead, detection of ECU
sleep mode an current profiling, all requiring high accuracy
and superior resolution

MODEL |
CP 30 |
CP 35 |
CP 305 |
Current Range (s) |
30A DC or AC (Peak) |
30A DC or AC (Peak) |
30/300A (RMS) |
Output
Sensitivity |
100mV/A |
100mV/A |
10 /
1mV/A |
Frequency Range |
DC to
20kHz (- 3dB) |
DC to
100kHz (-0.5dB) |
DC to
20kHz (-3dB) |
Resolution |
± 1mA |
± 1mA |
± 50 / ± 100mA |
Basic Accuracy |
± 1% of reading ±
2mA |
± 1% of reading ±
2mA |
± 1% of reading ± 50 / ± 100mA |
Conductor position sensitivity |
<
±1% relative to center reading |
<
±1% relative to center reading |
<
±1% relative to center reading |
Phase
shift (up to 1kHz) |
< 2
degrees |
< 2
degrees |
< 2
degrees |
LLoad
Impedance |
> 100
kOhms |
> 100
kOhms |
> 100
kOhms |
Output
connection |
Safety
4mm plugs |
Safety
BNC connector |
Safety
BNC connector |

|