Measured Parameters
  • (4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, 256 samples/cycle, 16 bit ADC
  • (4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
  • 1 MHz High Speed Sampling, 14 bit ADC
  • Frequency Range, 10m Hz resolution, 15-20 Hz, 45-65 Hz, or 350-450 Hz
  • Phase Lock Loop - Generator tracking
  • Phase Lock Loop - Standard PQ mode
Monitoring Compliance
  • IEEE 1159
  • IEC 61000-4-30 Class A
  • EN50160 Quality of Supply
  • Current Inrush / Energization
  • Voltage Fault recording
  • Long Term Monitoring w/min/max/avg
  • Continuous Data Logging
Power Quality Triggers
  • Cycle-by-cycle analysis
  • 256 samples/cycle; 1/2 cycle RMS steps 
  • L-L, L-N, N-G RMS Variations: Sags/swells/interruptions)
  • RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
  • Waveshape Recordings (32 pre-fault, 10K post-fault  cycles)
  • Low and Medium Frequent Transients - V & I
  • High Frequency Transients - V & I, 3% FS trigger
  • Harmonics Summary Parameters
  • Cross trigger V & I channels
  • RMS Event Characterization (IEEE or IEC)
  • Transient Event Characterization
Distortion / Energy / Power
  • W, VA, VAR, TPF, DPF, Demand, Energy, etc.
  • IEEE 1459 Parameters of distorted and unbalanced
  • Harmonics/Interharmonics per IEC 61000-4-7
  • THD/Harmonic Spectrum (V,I,W) to 63rd
  • TID /Interharmonic Spectrum (V,I) to 63rd
  • Flicker per IEC 61000-4-15 (Pst,Plt,Sliding Plt)
  • Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
  • Unbalance (max. rms deviation) & sequencing components
  • 5 User Spec Harmonics or Signaling Frequency
  • Vector/Arithmetic/Coincident Parameters
Available Languages
  • English, French, Italian, German, Spanish, Swedish, Finnish, Chinese, Japanese, Korean
General Specifications
  • Size (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3 cm)
  • Weight: 4.2 pounds (1.9 kg)
  • Operating Temperature: 0°  to 50° C (32° to 122°  F )
  • Storage Temperature: -20°  to 55° C (4° to 131°  F)
  • Humidity: 10 to 90% non-condensing
  • System Time Clock-Crystal controlled-1 second resolution
  • Charger /Battery Eliminator: 90-264 VAC 47-63 Hz
  • Display: LCD color touch screen
  • Memory options (must have one): Compact Flash, up to 32GB, 4GB min
Standard Package
  • Power Xplorer 5
  • Power Supply and Battery Backup
  • Bracket/Stand
  • Soft Carry Case
  • Simplified Userguide
  • Dranview Software
  • CF Card 4 GB
  • Clamp on CT/DranFlex (Optional)
  • Voltage Lead (red, yellow, blue, gray, white)
  • Interconnect Cable
  • Alligator Clips

 

 

 

 

 

 

Download