CLAMP CT's - AC

The current probes shown above have a 1.5V output, Dranetz Hypertronics connector, 3 meter cable and are directly compatible with the following Dranetz products:
Portable Power Quality Analyzers: Dranetz HDPQ family, PowerXplorer, PowerGuide, PowerVisa, Energy Platform, PP4300, 658 with CA4300 adapter.

 

 

Model: TR-2500B 10A to 500Arms

Range / Amplitude Accuracy / Phase Accuracy:

  • 100A to 500A / ±1% / ±1.5°
  • 10A to 100A / ±2% / ±3.0°

Frequency Range: 40Hz to 50kHz

Maximum Conductor Size: 50mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: TR-2500B

 

Model: TR-2501B 100mA to 1.2Arms

Range / Amplitude Accuracy / Phase Accuracy:

  • 1.2/ ±1.5% / ±2.0°
  • 100mA / ±2% / ±3.0°

Frequency Range: 40Hz to 50kHz

Maximum Conductor Size: 15mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: TR-2501B

 

Model: TR-2510B 1A to 10Arms

Range / Amplitude Accuracy / Phase Accuracy:

  • 5A to 10A/ ±1.2% / ±1.5°
  • 1A to 5A / ±1.2% / ±1°

Frequency Range: 40Hz to 50kHz

Maximum Conductor Size: 15mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: TR-2510B

 

 

 

Model: TR-2520B 100A to 3000Arms

Range / Amplitude Accuracy / Phase Accuracy:

Frequency Range: 40Hz to 50kHz

Maximum Conductor Size: 72mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: TR-2520B

 

Model: TR-2530B 20A to 300Arms

Range / Amplitude Accuracy / Phase Accuracy:

  • 50A to 300A/ ±1.0% / ±0.5°
  • 20A to 30A / ±1.5% / ±0.6°

Frequency Range: 30Hz to 50kHz

Maximum Conductor Size: 54mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: TR-2530

 

Model: TR-2540B 10A to 1000Arms

Range / Amplitude Accuracy / Phase Accuracy:

  • 100A to 1000A/ ±1.0% / ±0.4°
  • 10A to 100A / ±1.5% / ±0.5°

Frequency Range: 30Hz to 50kHz

Maximum Conductor Size: 54mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: TR-2540B

 

Model: TR-2550B 1A to 100Arms

Range / Amplitude Accuracy / Phase Accuracy:

  • 10A to 100A/ ±1.0% / ±2.5°
  • 1A to 10A / ±2.0% / ±5.0°

Frequency Range: 40Hz to 50kHz

Maximum Conductor Size: 15mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: TR-2550B

 

Clamp CT's - AC/DC

The current probes shown above have a 1.5V output, Dranetz Hypertronics connector, 2 meter cable and are directly compatible with the following Dranetz products:
Portable Power Quality Analyzers: Dranetz HDPQ family, PowerXplorer, PowerGuide, PowerVisa, PowerGuia, Energy Platform, PP4300, 658 with CA4300 adapter.

 

Model: PR150B 15A to 150A

Range / Amplitude Accuracy / Phase Accuracy:

  • 15A to 150A/ ±1.0% / ±3.0.°

Frequency Range: DC to 5kHz

Maximum Conductor Size: 52mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: PR150B

Model: PR1500B 150A to 1500A

Range / Amplitude Accuracy / Phase Accuracy:

  • 150A to 1500A/ ±1.0% / ±1.0°

Frequency Range: DC to 5kHz

Maximum Conductor Size: 52mm dia.

Rated Voltage: 600V Max.

Connector / Output: 1.5V

Datasheet: PR1500B

Split Core Current Tranformers

 

 

Part No. PQ4LN

Product: Precision Split Current Transformer

Low Input Amps:1A, 5A, 10A with Low Voltage Output

  • Accuracy: 0.5%
  • Phase Shift: < 60° (Typical)
  • Removable Leg - Easy to Install
  • Frequency: 50Hz to 1kHz
  • Excellent Low Current Sensitivity

Datasheet:

Part No. PQLCF45

Product: Split Core Current Transformer

Low Input Amps:1A, 5A, 10A with Low Voltage Output

  • Accuracy: 0.5%
  • Phase Shift: <0.5° (Typical)
  • Removable Leg - Easy to Install
  • Frequency: 45Hz to 1kHz
  • Excellent Low Current Sensitivity
  • UL 916 Listed

Datasheet:PQLCF45

POWER QUALITY (THAILAND) CO., LTD. All Rights Reserved 2019